- WIX CREATE MSI WRAPPER HOW TO
- WIX CREATE MSI WRAPPER VERIFICATION
- WIX CREATE MSI WRAPPER CODE
- WIX CREATE MSI WRAPPER LICENSE
How To: Read a Registry Entry During Installation.How To: Get the parent directory of a file search.How To: Reference another DirectorySearch element.How To: NGen Managed Assemblies During Installation.How To: Create a Shortcut on the Start Menu.How To: Check the Version Number of a File During Installation.Building a Custom Bootstrapper Application.Using WiX Standard Bootstrapper Application Variables.Customize the WiX Standard Bootstrapper Application Layout.Changing the WiX Standard Bootstrapper Application Branding.
WIX CREATE MSI WRAPPER LICENSE
Specifying the WiX Standard Bootstrapper Application License.Working with WiX Standard Bootstrapper Application.Author Bootstrapper Application for a Bundle.Building WiX Projects In Team Foundation Build.Integrating WiX Projects Into Daily Builds.Reading the Default WiX Project Template.
WIX CREATE MSI WRAPPER CODE
this is just for demonstration purposes.Īssert.AreEqual(0, result.ExitCode, "Actual exit code did not match expected exit code") Note: checking for an exit code of 0 is done implicitly in the Run() method but Use the Result object to verify the exit code Run Smoke and keep a reference to the Result object that is returned by the Run() method WixMessage LGHT1076 = new WixMessage(1076, "ICE1000: Component 'ExtraICE.0.ProductComponent' installs into directory 'TARGETDIR', which will get installed into the volume with the most free space unless explicitly set.", ) Smoke smoke = new Define the expected ICE error String msi = Builder.BuildPackage(testDirectory, "product.wxs", "product.msi", null, "-sval") Pass the -sval argument to delay validation until Smoke is run String testDirectory = Build the MSI that will be run against Smoke.
WIX CREATE MSI WRAPPER HOW TO
The following example shows how to verify that Smoke catches a particular ICE violation and how to use the Result object to perform further verification. Verifier.VerifyQuery(light.OutputFile, query, ".NET Foundation") String query = "SELECT `Value` FROM `Property` WHERE `Property` = 'Manufacturer'"
WIX CREATE MSI WRAPPER VERIFICATION
Query the resulting MSI for verification WixMessage LGHT1079 = new WixMessage(1079, ) Define the Light warning that we expect to see Ĭandle candle = new Create a Light object that uses some properties of the Candle object It also demonstrates how to check for a warning from Light and query the resuling MSI. The following example shows how to build an MSI using the Candle and Light wrapper classes. Verifier.VerifyResults(expectedMSI, actualMSI) Įxample: Check for a Warning and Query an MSI String expectedMSI = Use the VerifyResults method to compare the actual and expected MSIs String actualMSI = The expected MSI to compare against Use the BuildPackage method to build an MSI from source The following example shows how to test building an MSI from WiX source. Example Tests Example: Build and Verify an MSI The solution should be opened from the WiX command window to ensure that the %WIX_ROOT% environment variable is set. WixTestsTools: A library of wrapper classes and verification methods used by the tests.The WixTests solution currently contains two projects: The test solution file, WixTests.sln, is located in %WIX_ROOT%\test\WixTests.sln. Tools: Tests for a particular tool's command line options.SharedData: Test data that is shared across multiple tests.QTests: Tests migrated from the previous test infrastructure.Building an MSI from source with Candle and Light. Integration: Tests for integration of two or more tools.The data and src directories are further organized by feature area: WixTestTools: contains source code for the WixTestTools library.src: contains source code for the tests.The root directory for the tests is %WIX_ROOT%\test. This document describes how to write tests for WiX. Previous page next page Writing WiX Tests